Freedom

  • 6 year tank warranty
  • 2 year parts warranty
  • Permits combined horizontal and vertical vent runs up to 35 feet.
  • Electrical power required for quiet modular blower.
  • Vents with PVC, CPVC or ABS Schedule 40 piping.
  • Available in natural and propane***.
  • 3" vent cap with screen supplied.
  • Everlast Blue™ PEX polymer dip tubes.
  • Minimum 1" foam insulation.
  • 110/120 Volt electrical system, with 5-foot cord, standard 3-prong male connector.
  • Factory installed safety valve (T&P Valve).
ENERGY-EFFICIENT POWER VENT RESIDENTIAL GAS WATER HEATERS

First hour ratings and recoveries are rounded to the nearest gallon.
40 and 50 gallon models have 3/4" inlet and outlet connections. 75 gallon model has 1" inlet and outlet connections.
*Propane gas input 55,000 BTU.
**Propane gas input 70,000 BTU.
***When ordering propane, change "N" to "P" in model number (6-40-PRVT).
†Shipped with 5' of 3" ABS Schedule 40 vent pipe, 90° elbow, vent cap with screen.


Venting System Requirements

  1. The water heater requires its own (separate) venting system.
  2. Venting cannot be connected to existing vent piping or chimney.
  3. Venting must terminate horizontally to the outdoors.
  4. For venting, 3" PVC, CPVC, ABS Schedule 40" pipe can be used. 52,500, 65,000 and 75,000 BTU models must use ABS piping and elbow supplied for the first 5'.
  5. Vertical and horizontal runs must be secured at 31/2' intervals.
  6. Vent piping cannot under any circumstances be run downhill.
  7. No more than three elbows can be used.
  8. Horizontal runs require a minimum 1/4" rise per foot.
  9. Vertical runs cannot exceed 20'.
  10. Total vertical and horizontal runs cannot exceed 35'.
  11. To comply with ANSI Standards install vent piping so that it can be visually inspected.

IMPORTANT! Combustion air and ventilation requirements for Power-Vent water heaters.

  • 18" min. in all directions from any obstructions that may interfere with ventilation.
  • Vent terminal shall terminate at least 3 feet above any forced air inlet located within 10 feet.
  • 18" min. from other gravity or natural appliance outlet vents when directly above or 135° to either side of center line vent.
  • 36" min. from any outlet vents when directly below or 45° to either side of center line.
  • 36" min. in all directions from any other forced air appliance outlet.
  • Provide clearance for servicing and proper operation of water heater.
  • Snow accumulation and drifting should be considered.
  • Vent termination must be within 4 feet of any items such as gas meters, gas valves or other gas regulating equipment.
  • 0" clearance for 3" PVC, ABS or CPVC Schedule 40 vent piping from combustible surfaces.
  • 12" min. from the ground, 18" from ceiling overhangs.
  • Power-vent terminal shall terminate at least 4 feet below, 4 feet horizontally from or 1 foot above any door, window or gravity air inlet into the building.
Power vent art